Desktop arm · Seeed Studio reBot DevArm project

reBot DevArm B601 DM — power-supply assembly

Record state

Public BOM audited. This is a source-bound system evidence record, not an independent rebuild.

Publication surface

Nested Markdown tables · commit-addressable.

Rebuild conclusion

No complete rebuild evidence package found.

IDENTITY + REVISION

The robot name is not the version boundary.

RCI preserves the exact source surface and revision conditions instead of applying one prototype or current product page to every unit.

Platform boundary

reBot DevArm B601 DM — power-supply assembly

Power-supply Consumables BOM and Printed Parts BOM inside hardware/reBot_B601_DM/readme.md at commit a0c709638a341d6b12b005f22f5592c4b1579f56; the broader arm mechanics remain a linked but separate surface.

Version state

Addressable source snapshot

The selected Markdown is commit-addressable but not tied to a numbered arm release, exact shipped configuration or power-supply serial.

Lifecycle boundary

Changes remain attached to the source.

The source says the arm ships without a power supply by default and presents a user-procured Mean Well-based solution; RCI does not treat that optional assembly as factory-included hardware.

Responsibility party

Seeed Studio reBot DevArm project

RCI maps the named public responsibility party; inclusion does not imply endorsement, partnership or unit-level verification.

VERSION & SUPPLY

No structured lifecycle relation selected yet.

Replacement, upgrade, EOL and regional procurement signals remain separate from current availability and as-built identity.

No positive lifecycle claim.

Absence here means the selected source set does not yet support one, not that the platform has no revisions or supply risk.

Strongest supported conclusion

A quantified regional power-supply list, named Mean Well model, connector and wiring specifications, three linked STEP enclosure files, print parameters and illustrated assembly sequence.

Largest rebuild gap: The subsystem is not the whole robot, user crimping remains required, electrical protection verification is absent, and no physical RCI safety or load test exists.

Editorial boundary: This record is deliberately labelled as a power subsystem. It does not establish electrical code compliance, safe user wiring, arm compatibility across revisions or a complete reBot DevArm build.

DISCLOSURE MATRIX

Twelve gates separate a parts list from a rebuild package.

Partial means a source contains useful material but does not close the exact revision, quantity, part identity or unit-level boundary.

Evidence dimensionStateWhat the state means here
Exact platform revisionPartialUseful information exists, but exactness, completeness or version binding remains incomplete.
Versioned BOM snapshotPartialUseful information exists, but exactness, completeness or version binding remains incomplete.
Line-item quantitiesPublishedThe selected responsibility-party surface publishes this dimension inside the recorded boundary.
Manufacturer part numbersPartialUseful information exists, but exactness, completeness or version binding remains incomplete.
Supplier linksPublishedThe selected responsibility-party surface publishes this dimension inside the recorded boundary.
Custom-part production filesPublishedThe selected responsibility-party surface publishes this dimension inside the recorded boundary.
Electrical interconnect definitionPublishedThe selected responsibility-party surface publishes this dimension inside the recorded boundary.
Software / firmware bindingNot applicableThis dimension is not applicable to the selected publication surface.
License boundaryPublishedThe selected responsibility-party surface publishes this dimension inside the recorded boundary.
Change, EOL and substitution historyPartialUseful information exists, but exactness, completeness or version binding remains incomplete.
Unit-level as-built manifestNot publishedThe selected sources do not publish this evidence dimension.
Independent rebuild evidenceNot publishedThe selected sources do not publish this evidence dimension.
BOM SURFACE

reBot B601 DM power-supply Consumables BOM plus Printed Parts BOM

The count below preserves the responsibility party's publication structure; it is not silently flattened into unique purchasable components.

Selected count

13 rows / list items

Ten consumable/purchased rows plus three printed enclosure rows. This is a subsystem list, not the entire arm BOM; assembly-step tables are excluded from the item count.

Format

Nested Markdown tables

RCI did not treat the publication format as a normalized database table.

Next evidence gate

Normalize without inventing.

Resolve exact part identity, quantity scope, placement, revision and substitution state while retaining nested assemblies, alternatives and generic groups as explicit boundaries.

As-built state

Not published

A public list does not establish what one serialised unit actually contained.

RELATION GRAPH

No manufacturer identity is safely linked from the selected rows.

These are responsibility-party BOM mentions, not partnership, endorsement, verified supply or exact-component equivalence.

Generic or unregistered identities remain unlinked.

RCI will add a relationship only after the source publishes a manufacturer identity that maps unambiguously to the directory.

ASSEMBLY + INTERFACE TOPOLOGY

5 bounded nodes and 4 source-supported interface relations.

RCI publishes a connection only when the selected responsibility-party source explicitly supports the endpoints or architecture. A BOM co-occurrence, component capability or engineering convention is not enough.

power node

Regional AC cord boundary

The selected DM power subsystem publishes one US-standard AC cord while requiring a locally compliant three-pin plug.

Identity boundary: Cord manufacturer, certifications, conductor size, fuse and suitability outside the cited region are not established.

Source rows: rebot-b601-power-power-cord

power node

Switched 3-in-1 IEC inlet and AC wiring

One quick-connect 3-in-1 IEC inlet plus three 10 cm 1.5 mm² red/blue/yellow conductors in the selected subsystem table.

Identity boundary: Exact inlet model, fuse rating, terminal type, conductor colour meaning, crimp quality, earth continuity, insulation and code compliance are not verified.

Source rows: rebot-b601-power-iec-inlet, rebot-b601-power-ac-wire

power node

Mean Well LRS-350-24 conversion stage

One LRS-350-24, responsibility-party-labelled 24 V / 14.6 A, inside the optional DM supply assembly.

Identity boundary: Serial, production revision, input selection, output trim, derating, thermal environment, protection trip behavior and measured output are not bound to one unit.

Source rows: rebot-b601-power-psu

power node

XT60E fixed-female DC output assembly

One XT60E fixed female plus 10 cm lug pigtail forms the enclosure DC output.

Identity boundary: Connector brand, polarity inspection, crimp/solder process, wire gauge, current acceptance and strain relief are not verified.

Source rows: rebot-b601-power-xt60-output

power node

XT30U-female to XT60-male arm adapter boundary

One adapter connects the supply-side XT60 output surface toward the arm-side XT30 input boundary.

Identity boundary: Polarity, connector gender at every mating surface, wire gauge, current rating, physical routing and arm revision compatibility are not verified.

Source rows: rebot-b601-power-xt30-xt60

From → toRelationPublished supportStill unresolved
Regional AC cord boundary → Switched 3-in-1 IEC inlet and AC wiringsource-to-targetpowerRegional three-conductor AC cord into switched IEC inletThe selected consumables table and assembly sequence place the AC cord at the 3-in-1 IEC inlet of the optional enclosure.Seeed-Projects/reBot-DevArm commit a0c709638a341d6b12b005f22f5592c4b1579f56Regional plug/fuse requirements, inlet model, conductor assignment, earth continuity, insulation, strain relief and code acceptance are not verified. RCI has not connected this assembly to mains.Physical validation: none.
Switched 3-in-1 IEC inlet and AC wiring → Mean Well LRS-350-24 conversion stagesource-to-targetpowerSwitched AC inlet through three user-crimped conductors to LRS-350-24The official assembly steps direct the builder to wire the IEC inlet and supply according to the published sequence using the listed AC conductors.Seeed-Projects/reBot-DevArm commit a0c709638a341d6b12b005f22f5592c4b1579f56Terminal map, input-voltage selection, fuse, lug/crimp process, torque, earth bonding, creepage, insulation and electrical inspection records are not frozen. RCI has not assembled or energized the mains side.Physical validation: none.
Mean Well LRS-350-24 conversion stage → XT60E fixed-female DC output assemblysource-to-targetpowerNominal 24 V DC output to fixed XT60E female assemblyThe subsystem BOM and assembly sequence identify the LRS-350-24 as the conversion stage and install the XT60 output in the front enclosure.Seeed-Projects/reBot-DevArm commit a0c709638a341d6b12b005f22f5592c4b1579f56DC polarity, output trim, wire gauge, crimp/solder method, terminal torque, current acceptance, fuse and measured output under load are not published or verified. RCI has not measured this path.Physical validation: none.
XT60E fixed-female DC output assembly → XT30U-female to XT60-male arm adapter boundarysource-to-targetpowerXT60 enclosure output through XT30U-female-to-XT60-male adapter toward arm inputThe fixed consumables table publishes one XT60E output assembly and one XT30U-female-to-XT60-male adapter cable for the optional supply path.Seeed-Projects/reBot-DevArm commit a0c709638a341d6b12b005f22f5592c4b1579f56The full mating sequence, polarity, wire gauge, connector current rating, strain relief, arm-side socket revision and load behavior are not physically verified. RCI has not connected the supply to an arm.Physical validation: none.
NORMALIZED BOM

13 source items converted into claim-bounded records.

Identity, quantity and installed-hardware boundaries remain separate fields; a generic source label is never promoted to an exact orderable model.

Source itemClassIdentityQuantity boundaryRole + unresolved evidence
Mean Well LRS-350-24 power supplyConsumables BOMpowerInstalled / build itemvariant-namedMean Well · LRS-350-24 · 24 V / 14.6 A1 unit1 source-table unit; not an RCI-verified as-built count.Arm external DC powerNo serialised as-built manifest or independent physical rebuild confirms this item in one unit.
US-standard AC power cordConsumables BOMcableInstalled / build itemgeneric-descriptionNo exact identity published1 unit1 source-table unit; not an RCI-verified as-built count.Mains input cableRegional plug and compliance boundary is US-specific in the selected row.
XT60E fixed female output assemblyConsumables BOMpowerInstalled / build itemvariant-namedXT60E female + lug / 10 cm / 4 mm lug hole1 unit1 source-table unit; not an RCI-verified as-built count.DC output portNo serialised as-built manifest or independent physical rebuild confirms this item in one unit.
1.5 mm² AC wiringConsumables BOMcableInstalled / build itemgeneric-descriptionred, blue and yellow · 10 cm3 unit3 source-table units; not an RCI-verified as-built count.Internal mains wiringUser crimping is required and pre-crimped leads are not included.
3-in-1 IEC inlet socketConsumables BOMpowerInstalled / build itemgeneric-descriptionquick-connect red switch / dual nuts1 unit1 source-table unit; not an RCI-verified as-built count.Switched fused mains inletNo serialised as-built manifest or independent physical rebuild confirms this item in one unit.
XT30-to-XT60 adapter cableConsumables BOMcableInstalled / build itemgeneric-descriptionXT30U female to XT60 male1 unit1 source-table unit; not an RCI-verified as-built count.Power adapter harnessNo serialised as-built manifest or independent physical rebuild confirms this item in one unit.
M4×6 stainless countersunk Phillips screwConsumables BOMfastenerInstalled / build itemvariant-namedM4×66 unit6 source-table units; not an RCI-verified as-built count.Power-enclosure fasteningNo serialised as-built manifest or independent physical rebuild confirms this item in one unit.
M3×8 stainless countersunk Phillips screwConsumables BOMfastenerInstalled / build itemvariant-namedM3×82 unit2 source-table units; not an RCI-verified as-built count.Output-port fasteningNo serialised as-built manifest or independent physical rebuild confirms this item in one unit.
M3×8 stainless pan-head Phillips screwConsumables BOMfastenerInstalled / build itemvariant-namedM3×82 unit2 source-table units; not an RCI-verified as-built count.IEC-inlet fasteningNo serialised as-built manifest or independent physical rebuild confirms this item in one unit.
M3×2.5 hex nutConsumables BOMfastenerInstalled / build itemvariant-namedM3×2.52 unit2 source-table units; not an RCI-verified as-built count.Power-enclosure fasteningNo serialised as-built manifest or independent physical rebuild confirms this item in one unit.
Front CoverPrinted Parts BOMcustom-mechanicalInstalled / build itemfile-identifiedDM-power-Top Cover.stp · PLA · 0.4 mm nozzle · 0.2 mm layer · 30% infill1 unit1 source-table unit; not an RCI-verified as-built count.Power-supply front enclosureNo serialised as-built manifest or independent physical rebuild confirms this item in one unit.
Rear CoverPrinted Parts BOMcustom-mechanicalInstalled / build itemfile-identifiedDM-power-Bottom Cover.stp · PLA · 0.4 mm nozzle · 0.2 mm layer · 30% infill1 unit1 source-table unit; not an RCI-verified as-built count.Power-supply rear enclosureNo serialised as-built manifest or independent physical rebuild confirms this item in one unit.
Front Cover SliderPrinted Parts BOMcustom-mechanicalInstalled / build itemfile-identifiedDM-power-Top Cover-Sliding Cover.stp · PLA · 0.4 mm nozzle · 0.2 mm layer · 30% infill1 unit1 source-table unit; not an RCI-verified as-built count.Power-supply service coverNo serialised as-built manifest or independent physical rebuild confirms this item in one unit.
SOURCE REGISTER

Every conclusion returns to a selected source.

Links point to the responsibility party's material. RCI does not republish third-party BOM rows, CAD or retailer content through this profile.

Correction path

Know a newer revision or an exact as-built record?

Corrections must identify the platform revision, source location and the exact field affected. Manufacturer or project-party clarification is displayed alongside independently sourced evidence without replacing the original boundary.

Send a documented correction →

Return to all robot systems · Machine-readable record