Power & Energy · Isolated regulated DC-DC converter module

Vicor

DCM3623T50M31C2T00

The full order code and temperature grade are retained. Electrical ratings do not prove one robot battery, harness, filter, thermal path, protection design or transient-load result.

Architecture

Isolated, regulated 3623 ChiP DC-DC module with 16–50 V input, nominal 28 V output and array-operation support

Identity

Vicor DCM3623T50M31C2T00 · Also: DCM3623 50 V 28 V 320 W T-grade

DECISION READINESS / 0.1

What this record can support today.

Coverage is computed from published, non-unknown fields. It measures the record—not product quality—and makes missing procurement evidence explicit.

Engineering field coverage64%

7 of 11 selected fields published

  • Official product sourcepublished
  • Lifecycle statepublished
  • Mechanical dimensions / mass / mountingpublished
  • Environmental operating limitspublished
  • Capacity / energymissing
  • Voltage boundarypublished
  • Continuous / pulse currentpublished
  • Cycle-life conditionmissing
  • Charging requirementsmissing
  • Connector / contact definitionmissing
  • Protection / BMS boundarypublished
Procurement field coverage15%

2 of 13 selected fields published

  • Official product / sales routepublished
  • Lifecycle statepublished
  • Exact orderable SKU / part numbermissing
  • Price with region, currency and quantitymissing
  • Lead time with check datemissing
  • Commercial availability / stock statemissing
  • Minimum order quantitymissing
  • Authorized distributor / sales channelmissing
  • CAD / STEP / interface drawingmissing
  • Certification with identifiermissing
  • MTBF / failure / reliability datamissing
  • Warranty termsmissing
  • PCN / EOL / replacement noticemissing

Coverage measures whether a selected public field is present with non-U evidence. It is not a product score, compatibility result, certification, availability confirmation or procurement recommendation. Download the complete readiness coverage JSON →

CLAIM LEDGER

Reported values, conditions attached.

Evidence state describes the claim—not the prestige of the company or document.

ClaimReported valueCondition / boundaryStateSource
Input voltage rangeinput_voltage16–50 VDCObserve startup, derating and protection boundaries in the datasheet.M · Manufacturer claimedVicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024
Checked 2026-08-13
Nominal output voltagenominal_output28.0 VDCExact configuration family.M · Manufacturer claimedVicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024
Checked 2026-08-13
Output trim rangetrim_range22.0–30.8 VDCExternal trim and operating conditions apply.M · Manufacturer claimedVicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024
Checked 2026-08-13
Maximum output poweroutput_power320 WThermal, input-voltage and operating conditions apply.M · Manufacturer claimedVicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024
Checked 2026-08-13
Continuous output currentcontinuous_output_current11.43 AAt nominal 28 V under applicable thermal and electrical conditions.M · Manufacturer claimedVicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024
Checked 2026-08-13
Peak efficiencypeak_efficiency93.6 %Peak manufacturer value; not efficiency over every load, voltage and temperature.M · Manufacturer claimedVicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024
Checked 2026-08-13
Input-to-output isolationisolation2250 VDCManufacturer isolation rating and test conditions apply.M · Manufacturer claimedVicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024
Checked 2026-08-13
Array operationarray_operationUp to 8 units / 2560 WRequires compliant array design; not a drop-in guarantee.M · Manufacturer claimedVicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024
Checked 2026-08-13
Packagepackage3623 ChiP through-hole; 38.72 × 22.80 × 7.21 mmModule mechanical envelope.M · Manufacturer claimedVicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024
Checked 2026-08-13
Massmass24 gManufacturer mechanical data.M · Manufacturer claimedVicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024
Checked 2026-08-13
Operating temperature gradetemperature_grade-40 to 125 °CT-grade exact order-code boundary; verify temperature definition and derating curves.M · Manufacturer claimedVicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024
Checked 2026-08-13
Protection functionsprotectionsOvervoltage, overcurrent, undervoltage, short-circuit and thermal shutdownProtection presence does not replace system fusing, wiring or hazard analysis.M · Manufacturer claimedVicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024
Checked 2026-08-13
Robot transient-load and harness enveloperobot_transient_envelopeNot published in cited public evidenceRCI checked the cited official public evidence on the verification date.No cited source defines one robot battery impedance, cable, fuse, EMI filter, motor-regeneration event, cooling path and transient profile.U · UnknownVicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024
Checked 2026-08-13
Independent robot power validationindependent_power_validationNot published in cited public evidenceRCI checked the cited official public evidence on the verification date.RCI has not powered, thermally instrumented, transient-tested or fault-tested this module.U · UnknownVicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024
Checked 2026-08-13

Known limits

What this record does not prove.

  • Live price, stock, MOQ and lead time are volatile procurement observations and are intentionally excluded from durable claims.
  • Peak efficiency and output power remain condition-dependent manufacturer values.
  • No RCI module, harness, thermal, transient or fault test exists.