Isolated, regulated 3623 ChiP DC-DC module with 16–50 V input, nominal 28 V output and array-operation support
Power & Energy · Isolated regulated DC-DC converter module
DCM3623T50M31C2T00
The full order code and temperature grade are retained. Electrical ratings do not prove one robot battery, harness, filter, thermal path, protection design or transient-load result.
Vicor DCM3623T50M31C2T00 · Also: DCM3623 50 V 28 V 320 W T-grade
What this record can support today.
Coverage is computed from published, non-unknown fields. It measures the record—not product quality—and makes missing procurement evidence explicit.
7 of 11 selected fields published
- Official product sourcepublished
- Lifecycle statepublished
- Mechanical dimensions / mass / mountingpublished
- Environmental operating limitspublished
- Capacity / energymissing
- Voltage boundarypublished
- Continuous / pulse currentpublished
- Cycle-life conditionmissing
- Charging requirementsmissing
- Connector / contact definitionmissing
- Protection / BMS boundarypublished
2 of 13 selected fields published
- Official product / sales routepublished
- Lifecycle statepublished
- Exact orderable SKU / part numbermissing
- Price with region, currency and quantitymissing
- Lead time with check datemissing
- Commercial availability / stock statemissing
- Minimum order quantitymissing
- Authorized distributor / sales channelmissing
- CAD / STEP / interface drawingmissing
- Certification with identifiermissing
- MTBF / failure / reliability datamissing
- Warranty termsmissing
- PCN / EOL / replacement noticemissing
Coverage measures whether a selected public field is present with non-U evidence. It is not a product score, compatibility result, certification, availability confirmation or procurement recommendation. Download the complete readiness coverage JSON →
Reported values, conditions attached.
Evidence state describes the claim—not the prestige of the company or document.
| Claim | Reported value | Condition / boundary | State | Source |
|---|---|---|---|---|
| Input voltage rangeinput_voltage | 16–50 VDC | Observe startup, derating and protection boundaries in the datasheet. | M · Manufacturer claimed | Vicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024 Checked 2026-08-13 |
| Nominal output voltagenominal_output | 28.0 VDC | Exact configuration family. | M · Manufacturer claimed | Vicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024 Checked 2026-08-13 |
| Output trim rangetrim_range | 22.0–30.8 VDC | External trim and operating conditions apply. | M · Manufacturer claimed | Vicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024 Checked 2026-08-13 |
| Maximum output poweroutput_power | 320 W | Thermal, input-voltage and operating conditions apply. | M · Manufacturer claimed | Vicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024 Checked 2026-08-13 |
| Continuous output currentcontinuous_output_current | 11.43 A | At nominal 28 V under applicable thermal and electrical conditions. | M · Manufacturer claimed | Vicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024 Checked 2026-08-13 |
| Peak efficiencypeak_efficiency | 93.6 % | Peak manufacturer value; not efficiency over every load, voltage and temperature. | M · Manufacturer claimed | Vicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024 Checked 2026-08-13 |
| Input-to-output isolationisolation | 2250 VDC | Manufacturer isolation rating and test conditions apply. | M · Manufacturer claimed | Vicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024 Checked 2026-08-13 |
| Array operationarray_operation | Up to 8 units / 2560 W | Requires compliant array design; not a drop-in guarantee. | M · Manufacturer claimed | Vicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024 Checked 2026-08-13 |
| Packagepackage | 3623 ChiP through-hole; 38.72 × 22.80 × 7.21 mm | Module mechanical envelope. | M · Manufacturer claimed | Vicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024 Checked 2026-08-13 |
| Massmass | 24 g | Manufacturer mechanical data. | M · Manufacturer claimed | Vicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024 Checked 2026-08-13 |
| Operating temperature gradetemperature_grade | -40 to 125 °C | T-grade exact order-code boundary; verify temperature definition and derating curves. | M · Manufacturer claimed | Vicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024 Checked 2026-08-13 |
| Protection functionsprotections | Overvoltage, overcurrent, undervoltage, short-circuit and thermal shutdown | Protection presence does not replace system fusing, wiring or hazard analysis. | M · Manufacturer claimed | Vicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024 Checked 2026-08-13 |
| Robot transient-load and harness enveloperobot_transient_envelope | Not published in cited public evidence | RCI checked the cited official public evidence on the verification date.No cited source defines one robot battery impedance, cable, fuse, EMI filter, motor-regeneration event, cooling path and transient profile. | U · Unknown | Vicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024 Checked 2026-08-13 |
| Independent robot power validationindependent_power_validation | Not published in cited public evidence | RCI checked the cited official public evidence on the verification date.RCI has not powered, thermally instrumented, transient-tested or fault-tested this module. | U · Unknown | Vicor DCM3623x50M31C2yzz Datasheet ↗Electrical, mechanical, thermal, protection and array-operation specifications · Revision 1.6, June 2024 Checked 2026-08-13 |
Known limits
What this record does not prove.
- Live price, stock, MOQ and lead time are volatile procurement observations and are intentionally excluded from durable claims.
- Peak efficiency and output power remain condition-dependent manufacturer values.
- No RCI module, harness, thermal, transient or fault test exists.