Power & Energy · Multicell battery monitoring and balancing IC

STMicroelectronics

L99BM114-TR

A battery-monitoring IC relevant to robot pack design whose public datasheet quantifies ADC, balancing and communication boundaries, while the cited humanoid transient article does not release raw traces or a complete test method.

Architecture

4-to-14-series-cell battery-monitoring AFE with parallel cell-voltage conversion, shunt-current ADC, passive balancing, isolated daisy chain and SPI

Identity

STMicroelectronics L99BM114 · Also: L99BM114

DECISION READINESS / 0.1

What this record can support today.

Coverage is computed from published, non-unknown fields. It measures the record—not product quality—and makes missing procurement evidence explicit.

Engineering field coverage55%

6 of 11 selected fields published

  • Official product sourcepublished
  • Lifecycle statepublished
  • Mechanical dimensions / mass / mountingmissing
  • Environmental operating limitspublished
  • Capacity / energymissing
  • Voltage boundarypublished
  • Continuous / pulse currentpublished
  • Cycle-life conditionmissing
  • Charging requirementsmissing
  • Connector / contact definitionmissing
  • Protection / BMS boundarypublished
Procurement field coverage15%

2 of 13 selected fields published

  • Official product / sales routepublished
  • Lifecycle statepublished
  • Exact orderable SKU / part numbermissing
  • Price with region, currency and quantitymissing
  • Lead time with check datemissing
  • Commercial availability / stock statemissing
  • Minimum order quantitymissing
  • Authorized distributor / sales channelmissing
  • CAD / STEP / interface drawingmissing
  • Certification with identifiermissing
  • MTBF / failure / reliability datamissing
  • Warranty termsmissing
  • PCN / EOL / replacement noticemissing

Coverage measures whether a selected public field is present with non-U evidence. It is not a product score, compatibility result, certification, availability confirmation or procurement recommendation. Download the complete readiness coverage JSON →

CLAIM LEDGER

Reported values, conditions attached.

Evidence state describes the claim—not the prestige of the company or document.

ClaimReported valueCondition / boundaryStateSource
Series cells monitoredcell_count4–14 cellsOne L99BM114 device.M · Manufacturer claimedL99BM114 multicell battery monitoring and balancing IC datasheet ↗DS14722 Rev 1: features, absolute/operating limits, electrical characteristics and ADC operation · DS14722 Rev 1 · July 2024 · 159 pages
Checked 2026-08-10
Maximum battery stack voltagestack_voltage64 VDatasheet headline operating boundary; circuit design must retain pin-level limits.M · Manufacturer claimedL99BM114 multicell battery monitoring and balancing IC datasheet ↗DS14722 Rev 1: features, absolute/operating limits, electrical characteristics and ADC operation · DS14722 Rev 1 · July 2024 · 159 pages
Checked 2026-08-10
Cell-voltage measurement rangecell_voltage_input_range0.1–5.0 VElectrical-characteristics boundary for VCELL.M · Manufacturer claimedL99BM114 multicell battery monitoring and balancing IC datasheet ↗DS14722 Rev 1: features, absolute/operating limits, electrical characteristics and ADC operation · DS14722 Rev 1 · July 2024 · 159 pages
Checked 2026-08-10
Cell-voltage ADC resolutioncell_voltage_resolution89 µVDatasheet design-information value; the table marks this entry as not tested.M · Manufacturer claimedL99BM114 multicell battery monitoring and balancing IC datasheet ↗DS14722 Rev 1: features, absolute/operating limits, electrical characteristics and ADC operation · DS14722 Rev 1 · July 2024 · 159 pages
Checked 2026-08-10
Cell-voltage accuracy plus driftcell_voltage_accuracy±2 mVVCELL 3.2–4.3 V and ambient −40 to +105°C; retain all datasheet test and supply conditions.M · Manufacturer claimedL99BM114 multicell battery monitoring and balancing IC datasheet ↗DS14722 Rev 1: features, absolute/operating limits, electrical characteristics and ADC operation · DS14722 Rev 1 · July 2024 · 159 pages
Checked 2026-08-10
Current ADCcurrent_adc18-bit differential ADC; ±150 mV input rangeShunt-based current channel; application current depends on the selected shunt and system design.M · Manufacturer claimedL99BM114 multicell battery monitoring and balancing IC datasheet ↗DS14722 Rev 1: features, absolute/operating limits, electrical characteristics and ADC operation · DS14722 Rev 1 · July 2024 · 159 pages
Checked 2026-08-10
Illustrative current rangecurrent_range_application±1500 ADatasheet application example with a 0.1 mΩ shunt; marked application-only and not tested.This is not an independently verified robot-pack current rating.M · Manufacturer claimedL99BM114 multicell battery monitoring and balancing IC datasheet ↗DS14722 Rev 1: features, absolute/operating limits, electrical characteristics and ADC operation · DS14722 Rev 1 · July 2024 · 159 pages
Checked 2026-08-10
Current-input errorcurrent_error±0.3 mV within ±60 mV; ±0.5% outside to ±150 mVElectrical-characteristics table; use the exact differential-input interval and test conditions.M · Manufacturer claimedL99BM114 multicell battery monitoring and balancing IC datasheet ↗DS14722 Rev 1: features, absolute/operating limits, electrical characteristics and ADC operation · DS14722 Rev 1 · July 2024 · 159 pages
Checked 2026-08-10
Voltage/current synchronization behaviorsynchronized_samplingVoltage conversion waits for a useful current sample; synchronized sample stored in CUR_INST_SynchOn-demand acquisition; the wait can extend to TCYCLEADC_CUR.Synchronization does not establish zero end-to-end system latency.M · Manufacturer claimedL99BM114 multicell battery monitoring and balancing IC datasheet ↗DS14722 Rev 1: features, absolute/operating limits, electrical characteristics and ADC operation · DS14722 Rev 1 · July 2024 · 159 pages
Checked 2026-08-10
Current conversion timecurrent_conversion_time328.25 µs typ.Datasheet design-information value; marked not tested.M · Manufacturer claimedL99BM114 multicell battery monitoring and balancing IC datasheet ↗DS14722 Rev 1: features, absolute/operating limits, electrical characteristics and ADC operation · DS14722 Rev 1 · July 2024 · 159 pages
Checked 2026-08-10
Internal passive-balancing currentbalance_currentUp to 200 mA/cellMaximum is bounded by junction temperature and external thermal design.M · Manufacturer claimedL99BM114 multicell battery monitoring and balancing IC datasheet ↗DS14722 Rev 1: features, absolute/operating limits, electrical characteristics and ADC operation · DS14722 Rev 1 · July 2024 · 159 pages
Checked 2026-08-10
External temperature inputstemperature_inputsUp to 7 NTC inputsManufacturer product/datasheet feature.M · Manufacturer claimedSTMicroelectronics L99BM114 product page ↗Product status, key features, ordering information and evaluation ecosystem · Observed 2026-08-10
Checked 2026-08-10
Communication interfacescommunication2.66 Mbit/s isolated daisy chain; SPI up to 5 MHzInterface headline values; physical isolation parts, topology and protocol timing remain system-level work.M · Manufacturer claimedL99BM114 multicell battery monitoring and balancing IC datasheet ↗DS14722 Rev 1: features, absolute/operating limits, electrical characteristics and ADC operation · DS14722 Rev 1 · July 2024 · 159 pages
Checked 2026-08-10
Maximum daisy-chain lengthdaisy_chain31 devicesManufacturer-published device-count boundary.M · Manufacturer claimedSTMicroelectronics L99BM114 product page ↗Product status, key features, ordering information and evaluation ecosystem · Observed 2026-08-10
Checked 2026-08-10
Operating ambient temperatureoperating_temperature−40 to +105 °CDatasheet operating range; thermal and accuracy conditions still apply.M · Manufacturer claimedL99BM114 multicell battery monitoring and balancing IC datasheet ↗DS14722 Rev 1: features, absolute/operating limits, electrical characteristics and ADC operation · DS14722 Rev 1 · July 2024 · 159 pages
Checked 2026-08-10
Package / order codepackageTQFP-EP64 10 × 10 × 1.0 mm; L99BM114-TRProduct ordering and package information.M · Manufacturer claimedSTMicroelectronics L99BM114 product page ↗Product status, key features, ordering information and evaluation ecosystem · Observed 2026-08-10
Checked 2026-08-10
Public raw transient tracespublic_raw_transient_tracesNot published in cited public evidenceRCI checked the cited public product, datasheet and manufacturer-authored article surfaces on the verification date.The article shows two plotted examples but does not link downloadable time-series traces.U · UnknownBattery Management Accuracy Strengthens Humanoid Robot Reliability ↗Manufacturer-authored article and two plotted transient examples · Published by Power Systems Design; authors affiliated with STMicroelectronics
Checked 2026-08-10
Complete public transient-test methodtransient_test_methodNot published in cited public evidenceRCI checked the cited public product, datasheet and manufacturer-authored article surfaces on the verification date.The article names laboratory-grade active-load equipment but does not publish its make/model, calibration record, acquisition sample rate, filter configuration or a numeric error metric.U · UnknownBattery Management Accuracy Strengthens Humanoid Robot Reliability ↗Manufacturer-authored article and two plotted transient examples · Published by Power Systems Design; authors affiliated with STMicroelectronics
Checked 2026-08-10
Independent robot-pack validationindependent_robot_validationNot published in cited public evidenceRCI checked the cited public product, datasheet and manufacturer-authored article surfaces on the verification date.The cited transient examples are manufacturer-authored and do not constitute an independent exact-pack or operating-humanoid validation.U · UnknownBattery Management Accuracy Strengthens Humanoid Robot Reliability ↗Manufacturer-authored article and two plotted transient examples · Published by Power Systems Design; authors affiliated with STMicroelectronics
Checked 2026-08-10

Known limits

What this record does not prove.

  • This record is an integrated circuit, not a complete robot battery pack or BMS.
  • The ±1500 A figure is an application-only datasheet illustration tied to a 0.1 mΩ shunt and is explicitly marked not tested.
  • The manufacturer-authored article provides two plots but no public raw traces, instrument identity, calibration, acquisition rate or numeric transient-error metric.
  • An article-level statement of no observable latency must not override datasheet conversion, synchronization-delay and filter-window boundaries.