M-platform two-dimensional scanning LiDAR with a shared modular form factor and a high-density region of interest
Perception & Sensing · Automotive-grade mid-range digital LiDAR
M2
The exact M2 page is retained, including the 10% reflectivity range condition, average angular sampling and single-return point rate. Platform-level qualification and supplier test-hour statements are not promoted to an independent M2 robot benchmark.
RoboSense M2 · Also: RoboSense M Platform M2, RS M2 mid-range LiDAR
What this record can support today.
Coverage is computed from published, non-unknown fields. It measures the record—not product quality—and makes missing procurement evidence explicit.
5 of 11 selected fields published
- Official product sourcepublished
- Lifecycle statepublished
- Mechanical dimensions / mass / mountingpublished
- Environmental operating limitsmissing
- Operating / detection rangepublished
- Resolution / sample ratepublished
- Field of viewmissing
- Accuracy / error definitionmissing
- Data interfacemissing
- Timing / synchronizationmissing
- Power input / consumptionmissing
2 of 13 selected fields published
- Official product / sales routepublished
- Lifecycle statepublished
- Exact orderable SKU / part numbermissing
- Price with region, currency and quantitymissing
- Lead time with check datemissing
- Commercial availability / stock statemissing
- Minimum order quantitymissing
- Authorized distributor / sales channelmissing
- CAD / STEP / interface drawingmissing
- Certification with identifiermissing
- MTBF / failure / reliability datamissing
- Warranty termsmissing
- PCN / EOL / replacement noticemissing
Coverage measures whether a selected public field is present with non-U evidence. It is not a product score, compatibility result, certification, availability confirmation or procurement recommendation. Download the complete readiness coverage JSON →
Reported values, conditions attached.
Evidence state describes the claim—not the prestige of the company or document.
| Claim | Reported value | Condition / boundary | State | Source |
|---|---|---|---|---|
| Modelmodel | M2 | Third mid-range LiDAR in the RoboSense M platform. | M · Manufacturer claimed | RoboSense M2 product specification ↗M2 range, angular sampling, point rate, mass, dimensions and platform-level qualification boundary · Live product page observed 2026-08-13 Checked 2026-08-13 |
| Headline maximum rangemaximum_range | 250 m | Manufacturer headline value; target and detection conditions are not stated beside this number. | M · Manufacturer claimed | RoboSense M2 product specification ↗M2 range, angular sampling, point rate, mass, dimensions and platform-level qualification boundary · Live product page observed 2026-08-13 Checked 2026-08-13 |
| Range at 10% reflectivityrange_10_percent | 200 m | Manufacturer comparison table condition. | M · Manufacturer claimed | RoboSense M2 product specification ↗M2 range, angular sampling, point rate, mass, dimensions and platform-level qualification boundary · Live product page observed 2026-08-13 Checked 2026-08-13 |
| Average angular resolution (H × V)angular_resolution | 0.1 × 0.2 deg | General scan field. | M · Manufacturer claimed | RoboSense M2 product specification ↗M2 range, angular sampling, point rate, mass, dimensions and platform-level qualification boundary · Live product page observed 2026-08-13 Checked 2026-08-13 |
| Average ROI angular resolution (H × V)roi_angular_resolution | 0.1 × 0.1 deg | Region-of-interest value, not the entire scan field. | M · Manufacturer claimed | RoboSense M2 product specification ↗M2 range, angular sampling, point rate, mass, dimensions and platform-level qualification boundary · Live product page observed 2026-08-13 Checked 2026-08-13 |
| Point ratepoint_rate | 1,575,000 points/s | Single-return mode. | M · Manufacturer claimed | RoboSense M2 product specification ↗M2 range, angular sampling, point rate, mass, dimensions and platform-level qualification boundary · Live product page observed 2026-08-13 Checked 2026-08-13 |
| Dimensionsdimensions | 111 × 110 × 45 mm | Depth × width × height. | M · Manufacturer claimed | RoboSense M2 product specification ↗M2 range, angular sampling, point rate, mass, dimensions and platform-level qualification boundary · Live product page observed 2026-08-13 Checked 2026-08-13 |
| Mass without cablemass | 690 ± 20 g | Manufacturer comparison table. | M · Manufacturer claimed | RoboSense M2 product specification ↗M2 range, angular sampling, point rate, mass, dimensions and platform-level qualification boundary · Live product page observed 2026-08-13 Checked 2026-08-13 |
| M1 Plus component commonality statementplatform_commonality | More than 90% | Manufacturer platform statement; this is not a field-replaceability or interoperability result. | M · Manufacturer claimed | RoboSense M2 product specification ↗M2 range, angular sampling, point rate, mass, dimensions and platform-level qualification boundary · Live product page observed 2026-08-13 Checked 2026-08-13 |
| Qualification statementqualification_boundary | M platform ISO 26262 ASIL B; scanning chip AEC-Q100 | Platform- and chip-level boundary exactly as stated; not generalized to a complete robot system. | M · Manufacturer claimed | RoboSense M2 product specification ↗M2 range, angular sampling, point rate, mass, dimensions and platform-level qualification boundary · Live product page observed 2026-08-13 Checked 2026-08-13 |
| Exact firmware, packet, clock, cable and robot integration identityrobot_integration_identity | Not published in cited public evidence | RCI checked the cited official public evidence on the verification date.The cited public page does not publish a complete firmware/SDK/packet version, timestamp path, synchronization accuracy, connector pinout or robot calibration. | U · Unknown | RoboSense M2 product specification ↗M2 range, angular sampling, point rate, mass, dimensions and platform-level qualification boundary · Live product page observed 2026-08-13 Checked 2026-08-13 |
| Independent RCI range and perception benchmarkindependent_sensor_benchmark | Not published in cited public evidence | RCI checked the cited official public evidence on the verification date.RCI has not received an M2, captured packets, measured range, audited calibration or validated localization and obstacle detection. | U · Unknown | RoboSense M2 product specification ↗M2 range, angular sampling, point rate, mass, dimensions and platform-level qualification boundary · Live product page observed 2026-08-13 Checked 2026-08-13 |
Known limits
What this record does not prove.
- The 250 m headline and 200 m at 10% reflectivity are separate claims and must remain separate.
- Average ROI sampling is not whole-field angular resolution or object-detection accuracy.
- No RCI physical sensor, packet, timing, calibration or robot-perception test exists.