Perception & Sensing · Stereo depth camera

RealSense

D455

A USB stereo-depth camera with a 95 mm baseline, global shutters and a published ideal range tied to accuracy context.

Architecture

Active IR stereo depth camera with RGB global shutter and IMU

Identity

RealSense Depth Camera D455 · Also: D455f family

CATEGORY SUPPLIER LANDSCAPE

9 known suppliers in this product family.

Stereo, active stereo, structured-light or time-of-flight cameras marketed for robotic or industrial 3D capture. The list is bounded to the current RCI manufacturer-directory universe and separates exact-model audited suppliers from confirmed product-line suppliers.

EXACT-MODEL AUDITED

5 suppliers

RealSense · Orbbec · Stereolabs · Basler · Zivid

PRODUCT-LINE CONFIRMED

4 suppliers

Photoneo · Luxonis · LUCID Vision Labs · IDS Imaging Development Systems

This is a bounded discovery set, not a claim to enumerate every company worldwide. Open the full supplier landscape and official routes →

DECISION READINESS / 0.1

What this record can support today.

Coverage is computed from published, non-unknown fields. It measures the record—not product quality—and makes missing procurement evidence explicit.

Engineering field coverage73%

8 of 11 selected fields published

  • Official product sourcepublished
  • Lifecycle statepublished
  • Mechanical dimensions / mass / mountingmissing
  • Environmental operating limitsmissing
  • Operating / detection rangepublished
  • Resolution / sample ratepublished
  • Field of viewpublished
  • Accuracy / error definitionpublished
  • Data interfacepublished
  • Timing / synchronizationpublished
  • Power input / consumptionmissing
Procurement field coverage38%

5 of 13 selected fields published

  • Official product / sales routepublished
  • Lifecycle statepublished
  • Exact orderable SKU / part numberpublished
  • Price with region, currency and quantitymissing
  • Lead time with check datemissing
  • Commercial availability / stock statemissing
  • Minimum order quantitymissing
  • Authorized distributor / sales channelpublished
  • CAD / STEP / interface drawingmissing
  • Certification with identifierpublished
  • MTBF / failure / reliability datamissing
  • Warranty termsmissing
  • PCN / EOL / replacement noticemissing

Coverage measures whether a selected public field is present with non-U evidence. It is not a product score, compatibility result, certification, availability confirmation or procurement recommendation. Download the complete readiness coverage JSON →

MODEL-LINKED PHYSICAL EVIDENCE

11 bounded physical-evidence records.

Publisher independence, identity precision and measurement scope vary by row. Results remain bounded by the disclosed specimen, setup, workload and metric; an inconclusive mapping is evidence associated with the catalog model, not verification of a manufacturer claim.

Measured resultConditionsClaim mappingSource
Independent depth-error behaviorindependent_depth_behaviorNoise increases with distance; accuracy degrades sharply at high surface inclinationsControlled checkerboard study plus TLS-referenced indoor mapping evaluation; results depend on distance and surface inclination.supportedThe catalog claim already carries a qualified external V source with its original condition and location.Geometric Accuracy Investigations of Intel RealSense Depth Cameras ↗Sections 4–6 and Figures 6–10
Checked 2026-08-10
Independent ISO 10360-13 P_S errorindependent_iso_ps_errorMean 2.47 mm; standard deviation 1.42 mmOne off-the-shelf D455 was tested indoors under controlled brightness over 500–1500 mm using the paper’s ISO 10360-13 procedure.supportedThe catalog claim already carries a qualified external V source with its original condition and location.Metrological Characterization and Comparison of D415, D455, L515 RealSense Devices in the Close Range ↗ISO 10360-13 close-range procedure, Table 4 and discussion
Checked 2026-08-10
Very-close sphere diameter errorvery_close_sphere_error9.58 mm average errorCalibrated 25.4 mm sphere; four positions in the 100–500 mm very-close range.inconclusiveThe 100–500 mm experiment is below the manufacturer-described 0.6–6 m ideal range and does not test the 6 m endpoint; it characterizes very-close behavior but cannot resolve the published ideal-range envelope.Metrological Characterization and Comparison of D415, D455, L515 RealSense Devices in the Close Range ↗Section 4.1, Table 3 and discussion
Checked 2026-08-24
ISO 10360-13 probing-form erroriso_pf_error12.33 mm mean; 2.43 mm standard deviationSphere artifact acquired across the paper’s 500–1500 mm measurement volume.inconclusiveISO probing-form error over 0.5–1.5 m is not the manufacturer’s percent depth-accuracy metric at 4 m, so the result cannot confirm or contradict the <2% at 4 m claim.Metrological Characterization and Comparison of D415, D455, L515 RealSense Devices in the Close Range ↗Section 4.2.1, Table 5
Checked 2026-08-24
ISO 10360-13 length-distortion erroriso_length_distortion6.83 mm mean; 5.78 mm standard deviationBall-bar artifact acquired in 12 positions within the 500–1500 mm measurement volume.inconclusiveBall-bar length distortion over 0.5–1.5 m uses a different artifact, distance and error definition from percent depth accuracy at 4 m.Metrological Characterization and Comparison of D415, D455, L515 RealSense Devices in the Close Range ↗Section 4.2.2, Table 6
Checked 2026-08-24
Flat-form distortionflat_form_distortion16.05 mm mean; 8.33 mm standard deviationWhite opaque planar artifact evaluated under the paper’s ISO-derived close-range procedure.inconclusiveFlat-form distortion is a surface-form result under an ISO-derived close-range procedure, not the cited percentage depth error at 4 m.Metrological Characterization and Comparison of D415, D455, L515 RealSense Devices in the Close Range ↗Section 4.2.3, Table 7 and discussion
Checked 2026-08-24
Systematic planar depth errorsystematic_depth_error−0.7 mm mean; 4.25 mm standard deviation; 34.24 mm rangePlanar target acquired at increasing distances from 100 to 1500 mm.supportedThe distance-swept planar experiment directly contributes independent, distance-bounded depth-error behavior to the existing independent-behavior claim; it does not address the separate high-inclination finding.Metrological Characterization and Comparison of D415, D455, L515 RealSense Devices in the Close Range ↗Section 4.3, Table 8
Checked 2026-08-24
Statue 3D-reconstruction errorstatue_reconstruction_error0.18 mm mean; 2.27 mm standard deviation; 20.55 mm rangeReconstructed statue compared with the study’s reference mesh after alignment.inconclusiveAligned mesh reconstruction error for one statue is object- and pipeline-dependent and cannot resolve the product-page depth-accuracy percentage at 4 m.Metrological Characterization and Comparison of D415, D455, L515 RealSense Devices in the Close Range ↗Section 4.4, Table 9
Checked 2026-08-24
Tangram 3D-reconstruction errortangram_reconstruction_error0.16 mm mean; 2.29 mm standard deviation; 10.39 mm rangeReconstructed tangram compared with the study’s reference mesh after alignment.inconclusiveAligned mesh reconstruction error for the tangram uses a different output, scene and metric from the manufacturer’s 4 m percentage depth-accuracy claim.Metrological Characterization and Comparison of D415, D455, L515 RealSense Devices in the Close Range ↗Section 4.4, Table 10
Checked 2026-08-24
Maximum depth output used in metrology testsmaximum_depth_output_used1280 × 720 depth output selectedD455 operated in the paper’s default preset with depth unit 10−3 and the maximum available depth resolution; frame rate was not independently reported.inconclusiveThe study independently demonstrates 1280 × 720 depth acquisition, but it does not report the frame rate or test the separate 848 × 480 at 90 fps mode; the compound output claim remains only partially resolved.Metrological Characterization and Comparison of D415, D455, L515 RealSense Devices in the Close Range ↗Section 3, device configuration immediately before Section 3.1
Checked 2026-08-24
Depth-FoV independent-measurement boundaryfov_review_boundaryNo independent D455 angular FoV measurement reportedThe paper physically tested D455 metrology, but its 87° × 58° Table 1 value is explicitly attributed to the Intel RealSense website.inconclusiveThe independent metrology paper used the exact D455 but explicitly attributes its 87° × 58° table value to Intel and does not publish a separate angular-field measurement.Metrological Characterization and Comparison of D415, D455, L515 RealSense Devices in the Close Range ↗Section 3, Table 1 attribution and characterization framework
Checked 2026-08-24
PROCUREMENT EVIDENCE / v0.4.0

Commercial facts, with volatility attached.

These fields come from current manufacturer surfaces. They are evidence records—not a live quote, stock check or purchasing recommendation.

FieldPublished valueCondition / boundaryVolatility / reviewSource
Ordering identifierordering_code999WCRRealSense regulatory product table identifies the D455 peripheral with ordering identifier 999WCR; regional package or channel suffixes are not inferred.medium90-day cycle
Due 2026-11-19
RealSense Regulatory Information ↗Product regulatory and trade-information table · D455 row
Checked 2026-08-21
Official sales routeauthorized_channelsBuy Online / Talk to SalesThe exact D455 product page exposes official purchase and sales-contact routes; this does not establish stock, distributor authorization in every region or lead time.high14-day cycle
Due 2026-09-04
RealSense D455 product page ↗Next Steps
Checked 2026-08-21
EU / UK declaration identifiercertificationRS-DoC-02Declaration issued 2026-02-10 for product model D455. This single declaration is not a complete global certification package.low365-day cycle
Due 2027-08-21
D455 EU and UK Declaration of Conformity ↗Document identity and product model
Checked 2026-08-21
  • No public price, stock state, lead time, MOQ, warranty term, MTBF or exact CAD/STEP file was captured in this wave.
CLAIM LEDGER

Reported values, conditions attached.

Evidence state describes the claim—not the prestige of the company or document.

ClaimReported valueCondition / boundaryStateSource
Ideal rangerange0.6–6 mManufacturer-described ideal range; not a hard detection limit.M · Manufacturer claimedRealSense D455 product page ↗Tech Specs
Checked 2026-08-09
Depth outputresolution_fps1280 × 720 up to 30 fps; 848 × 480 up to 90 fpsMaximum frame rate depends on resolution.M · Manufacturer claimedRealSense D455 product page ↗Tech Specs
Checked 2026-08-09
Depth field of viewfov87 × 58 °Horizontal × vertical.M · Manufacturer claimedRealSense D455 product page ↗Tech Specs
Checked 2026-08-09
Data connectorinterfaceUSB-C 3.1 Gen 1No additional condition stated in the selected source.M · Manufacturer claimedRealSense D455 product page ↗Tech Specs
Checked 2026-08-09
Depth accuracyaccuracy<2% at 4 mManufacturer condition shown on the product page; see datasheet footnote for full method.M · Manufacturer claimedRealSense D455 product page ↗Tech Specs
Checked 2026-08-09
Motion sensing / synchronizationsyncBosch BMI055 IMU; multi-camera use describedProduct page does not turn this into a universal host-level synchronization guarantee.M · Manufacturer claimedRealSense D455 product page ↗Tech Specs
Checked 2026-08-09
SDK / firmware support boundarysoftware_supportFirmware ≥5.17.3.10; librealsense ≥v2.58.3The v2.58.3 beta release support table lists D455 USB with firmware 5.17.3.10 or later and SDK v2.58.3 or later; its supported JetPack rows are 5.0.2, 6.0, 6.1, 6.2 and 7.0. The official D400 firmware table separately associates firmware 5.17.3.10 with SDK 2.58.1; RCI preserves both source statements.A platform support table is not an exact Seeed J4012 carrier-image, kernel, bandwidth, timing or long-run stability validation.M · Manufacturer claimedRealSense SDK 2.0 beta (v2.58.3) ↗Additional source 1 ↗Supported Platforms and Supported Cameras tables; D455 USB row · v2.58.3 beta · published 2026-07-19 · commit dfd6aa9
Checked 2026-08-10
Independent depth-error behaviorindependent_depth_behaviorNoise increases with distance; accuracy degrades sharply at high surface inclinationsControlled checkerboard study plus TLS-referenced indoor mapping evaluation; results depend on distance and surface inclination.This verifies behavior under the paper’s setup, not the manufacturer’s entire range claim.V · Independently verifiedGeometric Accuracy Investigations of Intel RealSense Depth Cameras ↗Sections 4–6 and Figures 6–10
Checked 2026-08-10
Independent ISO 10360-13 P_S errorindependent_iso_ps_errorMean 2.47 mm; standard deviation 1.42 mmOne off-the-shelf D455 was tested indoors under controlled brightness over 500–1500 mm using the paper’s ISO 10360-13 procedure.This is a device- and setup-bounded close-range result; it does not validate every D455 unit, the full 6 m ideal range or every depth-error metric.V · Independently verifiedMetrological Characterization and Comparison of D415, D455, L515 RealSense Devices in the Close Range ↗ISO 10360-13 close-range procedure, Table 4 and discussion
Checked 2026-08-10

Known limits

What this record does not prove.

  • The stated ideal range and accuracy are not interchangeable with maximum detectable distance.
  • Resolution and frame-rate maxima cannot be combined arbitrarily.
  • SDK platform support does not establish exact D455 × J4012 compatibility; freeze and test the carrier image, kernel, SDK, firmware and stream workload.