Interfaces & Integration · USB-to-CAN/CAN FD interface

PEAK-System Technik

PCAN-USB FD IPEH-004022

The USB-A order number is separated from the USB-C variant. Bus-rate, isolation and timestamp specifications do not establish a robot protocol, cabling, termination or end-to-end synchronized latency.

Architecture

Single high-speed CAN physical interface with FPGA CAN FD controller, NXP TJA1044GT transceiver, USB-A host connection and galvanic isolation

Identity

PEAK-System PCAN-USB FD (USB-A) · Also: IPEH-004022, PCAN-USB FD USB-A

DECISION READINESS / 0.1

What this record can support today.

Coverage is computed from published, non-unknown fields. It measures the record—not product quality—and makes missing procurement evidence explicit.

Engineering field coverage58%

7 of 12 selected fields published

  • Official product sourcepublished
  • Lifecycle statepublished
  • Mechanical dimensions / mass / mountingmissing
  • Environmental operating limitspublished
  • Supported protocolpublished
  • Channel configurationmissing
  • Bus / data ratemissing
  • Timestamp / latencypublished
  • Electrical isolationpublished
  • Connector / host interfacepublished
  • Driver / software supportmissing
  • Power input / consumptionmissing
Procurement field coverage15%

2 of 13 selected fields published

  • Official product / sales routepublished
  • Lifecycle statepublished
  • Exact orderable SKU / part numbermissing
  • Price with region, currency and quantitymissing
  • Lead time with check datemissing
  • Commercial availability / stock statemissing
  • Minimum order quantitymissing
  • Authorized distributor / sales channelmissing
  • CAD / STEP / interface drawingmissing
  • Certification with identifiermissing
  • MTBF / failure / reliability datamissing
  • Warranty termsmissing
  • PCN / EOL / replacement noticemissing

Coverage measures whether a selected public field is present with non-U evidence. It is not a product score, compatibility result, certification, availability confirmation or procurement recommendation. Download the complete readiness coverage JSON →

MODEL-LINKED PHYSICAL EVIDENCE

1 bounded physical-evidence record.

Publisher independence, identity precision and measurement scope vary by row. Results remain bounded by the disclosed specimen, setup, workload and metric; an inconclusive mapping is evidence associated with the catalog model, not verification of a manufacturer claim.

Measured resultConditionsClaim mappingSource
Independent real-system experimentindependent_physical_evidencePhysical USB-CAN latency and message-transfer behavior measuredPCAN-USB FD connected to a real CAN setup; host and driver effects included.inconclusiveThe record establishes bounded physical evidence for the named model, but the experiment does not reproduce the catalogued claim metric and conditions; the claim remains inconclusive.A Survey on Media Access Solutions for CAN Penetration Testing ↗Hardware setup and interface measurements
Checked 2026-08-26
CLAIM LEDGER

Reported values, conditions attached.

Evidence state describes the claim—not the prestige of the company or document.

ClaimReported valueCondition / boundaryStateSource
Order numberorder_numberIPEH-004022USB-A connector variant.M · Manufacturer claimedPEAK-System PCAN-USB FD ↗Technical specifications and exact USB-A scope-of-supply order number IPEH-004022 · Live product page observed 2026-08-13
Checked 2026-08-13
Host interfacehost_interfaceHigh-speed USB 2.0, USB-AUSB 1.1 and USB 3.0 compatibility is also stated.M · Manufacturer claimedPEAK-System PCAN-USB FD ↗Technical specifications and exact USB-A scope-of-supply order number IPEH-004022 · Live product page observed 2026-08-13
Checked 2026-08-13
CAN supportcan_standardCAN 2.0 A/B and CAN FD; ISO and non-ISO CAN FD switchableManufacturer technical specifications.M · Manufacturer claimedPEAK-System PCAN-USB FD ↗Technical specifications and exact USB-A scope-of-supply order number IPEH-004022 · Live product page observed 2026-08-13
Checked 2026-08-13
CAN FD data-field bit-rate rangecan_fd_rate25 kbit/s to 12 Mbit/sUp to 64 data bytes per CAN FD frame.M · Manufacturer claimedPEAK-System PCAN-USB FD ↗Technical specifications and exact USB-A scope-of-supply order number IPEH-004022 · Live product page observed 2026-08-13
Checked 2026-08-13
Classic CAN bit-rate rangeclassic_can_rate25 kbit/s to 1 Mbit/sHigh-speed CAN physical layer.M · Manufacturer claimedPEAK-System PCAN-USB FD ↗Technical specifications and exact USB-A scope-of-supply order number IPEH-004022 · Live product page observed 2026-08-13
Checked 2026-08-13
Timestamp resolutiontimestamp_resolution1 µsResolution is not the same as synchronized system accuracy.M · Manufacturer claimedPEAK-System PCAN-USB FD ↗Technical specifications and exact USB-A scope-of-supply order number IPEH-004022 · Live product page observed 2026-08-13
Checked 2026-08-13
CAN transceivertransceiverNXP TJA1044GTExact product-page hardware statement.M · Manufacturer claimedPEAK-System PCAN-USB FD ↗Technical specifications and exact USB-A scope-of-supply order number IPEH-004022 · Live product page observed 2026-08-13
Checked 2026-08-13
Galvanic isolationisolationUp to 500 VPC-to-CAN-bus isolation claim.M · Manufacturer claimedPEAK-System PCAN-USB FD ↗Technical specifications and exact USB-A scope-of-supply order number IPEH-004022 · Live product page observed 2026-08-13
Checked 2026-08-13
CAN connectorconnectorD-Sub 9-pin, CiA 106Physical connector statement.M · Manufacturer claimedPEAK-System PCAN-USB FD ↗Technical specifications and exact USB-A scope-of-supply order number IPEH-004022 · Live product page observed 2026-08-13
Checked 2026-08-13
Operating temperature rangetemperature-40 to +85 °CManufacturer extended range.M · Manufacturer claimedPEAK-System PCAN-USB FD ↗Technical specifications and exact USB-A scope-of-supply order number IPEH-004022 · Live product page observed 2026-08-13
Checked 2026-08-13
Robot protocol, cable and termination configurationrobot_bus_configurationNot published in cited public evidenceRCI checked the cited official public evidence on the verification date.The interface product page does not establish CANopen/J1939/vendor protocol, database, bus topology, cable, termination, scheduler or host application.U · UnknownPEAK-System PCAN-USB FD ↗Technical specifications and exact USB-A scope-of-supply order number IPEH-004022 · Live product page observed 2026-08-13
Checked 2026-08-13
Independent timing and fault-recovery validationindependent_bus_testNot published in cited public evidenceRCI checked the cited official public evidence on the verification date.RCI has not captured traffic, measured latency, synchronized timestamps or injected bus faults with this device.U · UnknownPEAK-System PCAN-USB FD ↗Technical specifications and exact USB-A scope-of-supply order number IPEH-004022 · Live product page observed 2026-08-13
Checked 2026-08-13

Known limits

What this record does not prove.

  • The USB-A and USB-C order numbers must not be merged.
  • Timestamp resolution is not an end-to-end timing-accuracy result.
  • No RCI physical capture, latency, synchronization or fault-injection test exists.