| Claim | Reported value | Condition / boundary | State | Source |
|---|---|---|---|---|
| CAN channelschannels | 1 | No additional condition stated in the selected source. | M · Manufacturer claimed | Kvaser U100P User’s Guide ↗Technical data table · 1.6 / 2026-02-18 Checked 2026-08-10 |
| Classical CAN bitratebus_bitrate | 10–1000 kbit/s | No additional condition stated in the selected source. | M · Manufacturer claimed | Kvaser U100P User’s Guide ↗Technical data table · 1.6 / 2026-02-18 Checked 2026-08-10 |
| CAN FD data-phase bitratecan_fd | Up to 8 Mbit/s | Requires correct physical-layer implementation. | M · Manufacturer claimed | Kvaser U100P User’s Guide ↗Technical data table · 1.6 / 2026-02-18 Checked 2026-08-10 |
| Host interfacehost_interface | USB 2.0 | USB bus powered. | M · Manufacturer claimed | Kvaser U100P User’s Guide ↗Technical data table · 1.6 / 2026-02-18 Checked 2026-08-10 |
| Timestamp resolutiontimestamp | 1 µs | Precision U100P variant. | M · Manufacturer claimed | Kvaser U100P User’s Guide ↗Technical data table · 1.6 / 2026-02-18 Checked 2026-08-10 |
| Reinforced galvanic isolationisolation | 5000 VAC rms for 60 s | Design/test statement in current documentation. | M · Manufacturer claimed | Kvaser U100P product page ↗Major features and technical specifications Checked 2026-08-10 |
| Maximum message ratemessage_rate | 20,000 messages/s | Per channel. | M · Manufacturer claimed | Kvaser U100P User’s Guide ↗Technical data table · 1.6 / 2026-02-18 Checked 2026-08-10 |
| Housing / operating temperatureenvironmental | IP67; −40 to +85°C | Mated CAN and USB connectors are separately listed as IP40 in the guide. | M · Manufacturer claimed | Kvaser U100P User’s Guide ↗Technical data table · 1.6 / 2026-02-18 Checked 2026-08-10 |
Known limits
What this record does not prove.
- The IP67 housing rating does not extend to the mated connectors, which are listed as IP40.
- USB host scheduling is not deterministic fieldbus timing.
- The base U100 has a different timestamp specification and must not be conflated with U100P.