Interfaces & Integration · Rugged USB-to-CAN FD interface

Kvaser

U100P

The active precision U100 variant, with reinforced isolation and a 1 μs timestamp that is materially different from the base U100 model.

Architecture

Single isolated CAN/CAN FD channel with USB 2.0 host transport, MagiSync and precision timestamping

Identity

Kvaser U100P · Also: EAN 73-30130-01174-8

CLAIM LEDGER

Reported values, conditions attached.

Evidence state describes the claim—not the prestige of the company or document.

ClaimReported valueCondition / boundaryStateSource
CAN channelschannels1No additional condition stated in the selected source.M · Manufacturer claimedKvaser U100P User’s Guide ↗Technical data table · 1.6 / 2026-02-18
Checked 2026-08-10
Classical CAN bitratebus_bitrate10–1000 kbit/sNo additional condition stated in the selected source.M · Manufacturer claimedKvaser U100P User’s Guide ↗Technical data table · 1.6 / 2026-02-18
Checked 2026-08-10
CAN FD data-phase bitratecan_fdUp to 8 Mbit/sRequires correct physical-layer implementation.M · Manufacturer claimedKvaser U100P User’s Guide ↗Technical data table · 1.6 / 2026-02-18
Checked 2026-08-10
Host interfacehost_interfaceUSB 2.0USB bus powered.M · Manufacturer claimedKvaser U100P User’s Guide ↗Technical data table · 1.6 / 2026-02-18
Checked 2026-08-10
Timestamp resolutiontimestamp1 µsPrecision U100P variant.M · Manufacturer claimedKvaser U100P User’s Guide ↗Technical data table · 1.6 / 2026-02-18
Checked 2026-08-10
Reinforced galvanic isolationisolation5000 VAC rms for 60 sDesign/test statement in current documentation.M · Manufacturer claimedKvaser U100P product page ↗Major features and technical specifications
Checked 2026-08-10
Maximum message ratemessage_rate20,000 messages/sPer channel.M · Manufacturer claimedKvaser U100P User’s Guide ↗Technical data table · 1.6 / 2026-02-18
Checked 2026-08-10
Housing / operating temperatureenvironmentalIP67; −40 to +85°CMated CAN and USB connectors are separately listed as IP40 in the guide.M · Manufacturer claimedKvaser U100P User’s Guide ↗Technical data table · 1.6 / 2026-02-18
Checked 2026-08-10

Known limits

What this record does not prove.

  • The IP67 housing rating does not extend to the mated connectors, which are listed as IP40.
  • USB host scheduling is not deterministic fieldbus timing.
  • The base U100 has a different timestamp specification and must not be conflated with U100P.