Interfaces & Integration · USB-to-CAN interface

HMS Networks / Ixxat

Ixxat USB-to-CAN V2 professional

A dual-channel classical-CAN adapter whose selected product specification does not claim CAN FD, making protocol-generation boundaries explicit.

Architecture

Dual isolated classical-CAN interfaces with USB 2.0 host transport and VCI/ECI driver ecosystem

Identity

HMS Ixxat USB-to-CAN V2 Professional · Also: 1.01.0283.22002

CATEGORY SUPPLIER LANDSCAPE

8 known suppliers in this product family.

CAN/CAN FD, industrial Ethernet and fieldbus interfaces, gateways or switches used to connect robot controllers and devices. The list is bounded to the current RCI manufacturer-directory universe and separates exact-model audited suppliers from confirmed product-line suppliers.

EXACT-MODEL AUDITED

5 suppliers

Kvaser · HMS Networks / Ixxat · PEAK-System Technik · Vector Informatik · Moxa

PRODUCT-LINE CONFIRMED

3 suppliers

Intrepid Control Systems · Softing Industrial · esd electronics

This is a bounded discovery set, not a claim to enumerate every company worldwide. Open the full supplier landscape and official routes →

DECISION READINESS / 0.1

What this record can support today.

Coverage is computed from published, non-unknown fields. It measures the record—not product quality—and makes missing procurement evidence explicit.

Engineering field coverage83%

10 of 12 selected fields published

  • Official product sourcepublished
  • Lifecycle statepublished
  • Mechanical dimensions / mass / mountingmissing
  • Environmental operating limitspublished
  • Supported protocolpublished
  • Channel configurationpublished
  • Bus / data ratepublished
  • Timestamp / latencypublished
  • Electrical isolationpublished
  • Connector / host interfacepublished
  • Driver / software supportpublished
  • Power input / consumptionmissing
Procurement field coverage15%

2 of 13 selected fields published

  • Official product / sales routepublished
  • Lifecycle statepublished
  • Exact orderable SKU / part numbermissing
  • Price with region, currency and quantitymissing
  • Lead time with check datemissing
  • Commercial availability / stock statemissing
  • Minimum order quantitymissing
  • Authorized distributor / sales channelmissing
  • CAD / STEP / interface drawingmissing
  • Certification with identifiermissing
  • MTBF / failure / reliability datamissing
  • Warranty termsmissing
  • PCN / EOL / replacement noticemissing

Coverage measures whether a selected public field is present with non-U evidence. It is not a product score, compatibility result, certification, availability confirmation or procurement recommendation. Download the complete readiness coverage JSON →

MODEL-LINKED PHYSICAL EVIDENCE

1 bounded physical-evidence record.

Publisher independence, identity precision and measurement scope vary by row. Results remain bounded by the disclosed specimen, setup, workload and metric; an inconclusive mapping is evidence associated with the catalog model, not verification of a manufacturer claim.

Measured resultConditionsClaim mappingSource
Independent real-system experimentindependent_physical_evidenceExact interface operated in a physical CANopen timing experimentUniversity laboratory CAN network with host-side timestamp and transfer-delay observations.inconclusiveThe record establishes bounded physical evidence for the named model, but the experiment does not reproduce the catalogued claim metric and conditions; the claim remains inconclusive.Experimental evaluation of CAN interface delay ↗Hardware list, method and delay results
Checked 2026-08-26
CLAIM LEDGER

Reported values, conditions attached.

Evidence state describes the claim—not the prestige of the company or document.

ClaimReported valueCondition / boundaryStateSource
High-speed CAN channelschannels2Two RJ45 interfaces with supplied D-Sub 9 adapter cables.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information
Checked 2026-08-10
Classical CAN bitratebus_bitrate10–1000 kbit/sCAN high-speed ISO 11898-2:2016.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information
Checked 2026-08-10
CAN controller modebus_protocolCAN 2.0 A/BThe selected configuration does not list CAN FD support.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information
Checked 2026-08-10
Host interfacehost_interfaceUSB 2.0 Hi-Speed, 480 Mbit/sCompatible with USB 1.1 and USB 3.x according to family documentation.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information
Checked 2026-08-10
TimestampingtimestampHigh-precision on-board timestampingNo numeric resolution is published in the selected product specification.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information
Checked 2026-08-10
Isolationisolation1 kV DC for 1 s / 500 V AC for 1 minManufacturer product specification.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information
Checked 2026-08-10
Operating temperatureenvironmental−20 to +70 °CNo additional condition stated in the selected source.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information
Checked 2026-08-10
Driver interfacessoftwareWindows VCI; Linux ECI / SocketCAN family supportExact platform support must be checked against the current driver release.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information
Checked 2026-08-10

Known limits

What this record does not prove.

  • The selected V2 professional record is classical CAN; do not infer CAN FD from other Ixxat products.
  • Timestamp precision is described qualitatively in the selected source.
  • Supplied adapter cables affect the physical connector seen by the robot.