Dual isolated classical-CAN interfaces with USB 2.0 host transport and VCI/ECI driver ecosystem
Interfaces & Integration · USB-to-CAN interface
Ixxat USB-to-CAN V2 professional
A dual-channel classical-CAN adapter whose selected product specification does not claim CAN FD, making protocol-generation boundaries explicit.
HMS Ixxat USB-to-CAN V2 Professional · Also: 1.01.0283.22002
Reported values, conditions attached.
Evidence state describes the claim—not the prestige of the company or document.
| Claim | Reported value | Condition / boundary | State | Source |
|---|---|---|---|---|
| High-speed CAN channelschannels | 2 | Two RJ45 interfaces with supplied D-Sub 9 adapter cables. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information Checked 2026-08-10 |
| Classical CAN bitratebus_bitrate | 10–1000 kbit/s | CAN high-speed ISO 11898-2:2016. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information Checked 2026-08-10 |
| CAN controller modebus_protocol | CAN 2.0 A/B | The selected configuration does not list CAN FD support. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information Checked 2026-08-10 |
| Host interfacehost_interface | USB 2.0 Hi-Speed, 480 Mbit/s | Compatible with USB 1.1 and USB 3.x according to family documentation. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information Checked 2026-08-10 |
| Timestampingtimestamp | High-precision on-board timestamping | No numeric resolution is published in the selected product specification. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information Checked 2026-08-10 |
| Isolationisolation | 1 kV DC for 1 s / 500 V AC for 1 min | Manufacturer product specification. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information Checked 2026-08-10 |
| Operating temperatureenvironmental | −20 to +70 °C | No additional condition stated in the selected source. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information Checked 2026-08-10 |
| Driver interfacessoftware | Windows VCI; Linux ECI / SocketCAN family support | Exact platform support must be checked against the current driver release. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information Checked 2026-08-10 |
Known limits
What this record does not prove.
- The selected V2 professional record is classical CAN; do not infer CAN FD from other Ixxat products.
- Timestamp precision is described qualitatively in the selected source.
- Supplied adapter cables affect the physical connector seen by the robot.