Dual isolated classical-CAN interfaces with USB 2.0 host transport and VCI/ECI driver ecosystem
Interfaces & Integration · USB-to-CAN interface
Ixxat USB-to-CAN V2 professional
A dual-channel classical-CAN adapter whose selected product specification does not claim CAN FD, making protocol-generation boundaries explicit.
HMS Ixxat USB-to-CAN V2 Professional · Also: 1.01.0283.22002
8 known suppliers in this product family.
CAN/CAN FD, industrial Ethernet and fieldbus interfaces, gateways or switches used to connect robot controllers and devices. The list is bounded to the current RCI manufacturer-directory universe and separates exact-model audited suppliers from confirmed product-line suppliers.
5 suppliers
Kvaser · HMS Networks / Ixxat · PEAK-System Technik · Vector Informatik · Moxa
3 suppliers
Intrepid Control Systems · Softing Industrial · esd electronics
This is a bounded discovery set, not a claim to enumerate every company worldwide. Open the full supplier landscape and official routes →
What this record can support today.
Coverage is computed from published, non-unknown fields. It measures the record—not product quality—and makes missing procurement evidence explicit.
10 of 12 selected fields published
- Official product sourcepublished
- Lifecycle statepublished
- Mechanical dimensions / mass / mountingmissing
- Environmental operating limitspublished
- Supported protocolpublished
- Channel configurationpublished
- Bus / data ratepublished
- Timestamp / latencypublished
- Electrical isolationpublished
- Connector / host interfacepublished
- Driver / software supportpublished
- Power input / consumptionmissing
2 of 13 selected fields published
- Official product / sales routepublished
- Lifecycle statepublished
- Exact orderable SKU / part numbermissing
- Price with region, currency and quantitymissing
- Lead time with check datemissing
- Commercial availability / stock statemissing
- Minimum order quantitymissing
- Authorized distributor / sales channelmissing
- CAD / STEP / interface drawingmissing
- Certification with identifiermissing
- MTBF / failure / reliability datamissing
- Warranty termsmissing
- PCN / EOL / replacement noticemissing
Coverage measures whether a selected public field is present with non-U evidence. It is not a product score, compatibility result, certification, availability confirmation or procurement recommendation. Download the complete readiness coverage JSON →
1 bounded physical-evidence record.
Publisher independence, identity precision and measurement scope vary by row. Results remain bounded by the disclosed specimen, setup, workload and metric; an inconclusive mapping is evidence associated with the catalog model, not verification of a manufacturer claim.
| Measured result | Conditions | Claim mapping | Source |
|---|---|---|---|
| Independent real-system experimentindependent_physical_evidence | Exact interface operated in a physical CANopen timing experimentUniversity laboratory CAN network with host-side timestamp and transfer-delay observations. | inconclusiveThe record establishes bounded physical evidence for the named model, but the experiment does not reproduce the catalogued claim metric and conditions; the claim remains inconclusive. | Experimental evaluation of CAN interface delay ↗Hardware list, method and delay results Checked 2026-08-26 |
Reported values, conditions attached.
Evidence state describes the claim—not the prestige of the company or document.
| Claim | Reported value | Condition / boundary | State | Source |
|---|---|---|---|---|
| High-speed CAN channelschannels | 2 | Two RJ45 interfaces with supplied D-Sub 9 adapter cables. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information Checked 2026-08-10 |
| Classical CAN bitratebus_bitrate | 10–1000 kbit/s | CAN high-speed ISO 11898-2:2016. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information Checked 2026-08-10 |
| CAN controller modebus_protocol | CAN 2.0 A/B | The selected configuration does not list CAN FD support. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information Checked 2026-08-10 |
| Host interfacehost_interface | USB 2.0 Hi-Speed, 480 Mbit/s | Compatible with USB 1.1 and USB 3.x according to family documentation. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information Checked 2026-08-10 |
| Timestampingtimestamp | High-precision on-board timestamping | No numeric resolution is published in the selected product specification. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information Checked 2026-08-10 |
| Isolationisolation | 1 kV DC for 1 s / 500 V AC for 1 min | Manufacturer product specification. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information Checked 2026-08-10 |
| Operating temperatureenvironmental | −20 to +70 °C | No additional condition stated in the selected source. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information Checked 2026-08-10 |
| Driver interfacessoftware | Windows VCI; Linux ECI / SocketCAN family support | Exact platform support must be checked against the current driver release. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information Checked 2026-08-10 |
Known limits
What this record does not prove.
- The selected V2 professional record is classical CAN; do not infer CAN FD from other Ixxat products.
- Timestamp precision is described qualitatively in the selected source.
- Supplied adapter cables affect the physical connector seen by the robot.