Interfaces & Integration · USB-to-CAN interface

HMS Networks / Ixxat

Ixxat USB-to-CAN V2 professional

A dual-channel classical-CAN adapter whose selected product specification does not claim CAN FD, making protocol-generation boundaries explicit.

Architecture

Dual isolated classical-CAN interfaces with USB 2.0 host transport and VCI/ECI driver ecosystem

Identity

HMS Ixxat USB-to-CAN V2 Professional · Also: 1.01.0283.22002

CLAIM LEDGER

Reported values, conditions attached.

Evidence state describes the claim—not the prestige of the company or document.

ClaimReported valueCondition / boundaryStateSource
High-speed CAN channelschannels2Two RJ45 interfaces with supplied D-Sub 9 adapter cables.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information
Checked 2026-08-10
Classical CAN bitratebus_bitrate10–1000 kbit/sCAN high-speed ISO 11898-2:2016.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information
Checked 2026-08-10
CAN controller modebus_protocolCAN 2.0 A/BThe selected configuration does not list CAN FD support.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information
Checked 2026-08-10
Host interfacehost_interfaceUSB 2.0 Hi-Speed, 480 Mbit/sCompatible with USB 1.1 and USB 3.x according to family documentation.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information
Checked 2026-08-10
TimestampingtimestampHigh-precision on-board timestampingNo numeric resolution is published in the selected product specification.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information
Checked 2026-08-10
Isolationisolation1 kV DC for 1 s / 500 V AC for 1 minManufacturer product specification.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information
Checked 2026-08-10
Operating temperatureenvironmental−20 to +70 °CNo additional condition stated in the selected source.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information
Checked 2026-08-10
Driver interfacessoftwareWindows VCI; Linux ECI / SocketCAN family supportExact platform support must be checked against the current driver release.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 professional product page ↗Technical specifications and ordering information
Checked 2026-08-10

Known limits

What this record does not prove.

  • The selected V2 professional record is classical CAN; do not infer CAN FD from other Ixxat products.
  • Timestamp precision is described qualitatively in the selected source.
  • Supplied adapter cables affect the physical connector seen by the robot.