USB 2.0 adapter with one isolated high-speed classical CAN channel and onboard timestamping
Interfaces & Integration · Single-channel USB classical-CAN interface
Ixxat USB-to-CAN V2 compact
A compact classical-CAN adapter with quantified isolation but only qualitative timestamp language in the selected documents.
HMS Ixxat USB-to-CAN V2 compact · Also: USB-to-CAN V2 compact
8 known suppliers in this product family.
CAN/CAN FD, industrial Ethernet and fieldbus interfaces, gateways or switches used to connect robot controllers and devices. The list is bounded to the current RCI manufacturer-directory universe and separates exact-model audited suppliers from confirmed product-line suppliers.
5 suppliers
Kvaser · HMS Networks / Ixxat · PEAK-System Technik · Vector Informatik · Moxa
3 suppliers
Intrepid Control Systems · Softing Industrial · esd electronics
This is a bounded discovery set, not a claim to enumerate every company worldwide. Open the full supplier landscape and official routes →
What this record can support today.
Coverage is computed from published, non-unknown fields. It measures the record—not product quality—and makes missing procurement evidence explicit.
9 of 12 selected fields published
- Official product sourcepublished
- Lifecycle statepublished
- Mechanical dimensions / mass / mountingmissing
- Environmental operating limitspublished
- Supported protocolpublished
- Channel configurationpublished
- Bus / data ratepublished
- Timestamp / latencyunknown
- Electrical isolationpublished
- Connector / host interfacepublished
- Driver / software supportpublished
- Power input / consumptionmissing
2 of 13 selected fields published
- Official product / sales routepublished
- Lifecycle statepublished
- Exact orderable SKU / part numbermissing
- Price with region, currency and quantitymissing
- Lead time with check datemissing
- Commercial availability / stock statemissing
- Minimum order quantitymissing
- Authorized distributor / sales channelmissing
- CAD / STEP / interface drawingmissing
- Certification with identifiermissing
- MTBF / failure / reliability datamissing
- Warranty termsmissing
- PCN / EOL / replacement noticemissing
Coverage measures whether a selected public field is present with non-U evidence. It is not a product score, compatibility result, certification, availability confirmation or procurement recommendation. Download the complete readiness coverage JSON →
1 bounded physical-evidence record.
Publisher independence, identity precision and measurement scope vary by row. Results remain bounded by the disclosed specimen, setup, workload and metric; an inconclusive mapping is evidence associated with the catalog model, not verification of a manufacturer claim.
| Measured result | Conditions | Claim mapping | Source |
|---|---|---|---|
| Independent real-system experimentindependent_physical_evidence | Multiple physical stations showed a reproducible three-minute production-test slowdownWindows 10 and LabVIEW production test; oscilloscope confirmed bus transfer; root cause not isolated. | inconclusiveThe record establishes bounded physical evidence for the named model, but the experiment does not reproduce the catalogued claim metric and conditions; the claim remains inconclusive. | USB to CAN V2 compact speed issues ↗User test configuration and observations Checked 2026-08-26 |
Reported values, conditions attached.
Evidence state describes the claim—not the prestige of the company or document.
| Claim | Reported value | Condition / boundary | State | Source |
|---|---|---|---|---|
| CAN channelschannels | 1 | Single high-speed CAN channel. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 compact product page ↗Protocol, host, isolation and driver specifications Checked 2026-08-10 |
| Classical CAN bitratebus_bitrate | 10–1000 kbit/s | High-speed CAN according to ISO 11898-2. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 compact Datasheet ↗D-Sub variant interface, isolation and environmental specifications Checked 2026-08-10 |
| CAN FD supportcan_fd | No | Selected V2 compact record is classical CAN. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 compact product page ↗Protocol, host, isolation and driver specifications Checked 2026-08-10 |
| Host interfacehost_interface | USB 2.0 Hi-Speed, 480 Mbit/s | Host scheduling and driver behavior still apply. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 compact Datasheet ↗D-Sub variant interface, isolation and environmental specifications Checked 2026-08-10 |
| Numeric timestamp resolutiontimestamp | Not published in cited specification | RCI checked the cited official specification on the verification date.The selected official specifications describe high-precision timestamping but do not publish a numeric resolution. | U · Unknown | HMS Ixxat USB-to-CAN V2 compact product page ↗Protocol, host, isolation and driver specifications Checked 2026-08-10 |
| Isolation withstandisolation | 1 kV DC for 1 s / 500 V AC for 1 min | Manufacturer datasheet value. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 compact Datasheet ↗D-Sub variant interface, isolation and environmental specifications Checked 2026-08-10 |
| Driver interfacessoftware | Windows VCI; Linux ECI / SocketCAN | Exact current distribution and kernel support must be checked. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 compact product page ↗Protocol, host, isolation and driver specifications Checked 2026-08-10 |
| Operating temperatureenvironmental | −20 to +70 °C | Manufacturer datasheet value. | M · Manufacturer claimed | HMS Ixxat USB-to-CAN V2 compact Datasheet ↗D-Sub variant interface, isolation and environmental specifications Checked 2026-08-10 |
Known limits
What this record does not prove.
- This V2 compact record does not support CAN FD.
- Timestamp precision is not numerically specified.
- The product page and cited D-Sub datasheet use different connector/order-number variants; the exact connector must be frozen in the BOM.