Interfaces & Integration · Single-channel USB classical-CAN interface

HMS Networks / Ixxat

Ixxat USB-to-CAN V2 compact

A compact classical-CAN adapter with quantified isolation but only qualitative timestamp language in the selected documents.

Architecture

USB 2.0 adapter with one isolated high-speed classical CAN channel and onboard timestamping

Identity

HMS Ixxat USB-to-CAN V2 compact · Also: USB-to-CAN V2 compact

CATEGORY SUPPLIER LANDSCAPE

8 known suppliers in this product family.

CAN/CAN FD, industrial Ethernet and fieldbus interfaces, gateways or switches used to connect robot controllers and devices. The list is bounded to the current RCI manufacturer-directory universe and separates exact-model audited suppliers from confirmed product-line suppliers.

EXACT-MODEL AUDITED

5 suppliers

Kvaser · HMS Networks / Ixxat · PEAK-System Technik · Vector Informatik · Moxa

PRODUCT-LINE CONFIRMED

3 suppliers

Intrepid Control Systems · Softing Industrial · esd electronics

This is a bounded discovery set, not a claim to enumerate every company worldwide. Open the full supplier landscape and official routes →

DECISION READINESS / 0.1

What this record can support today.

Coverage is computed from published, non-unknown fields. It measures the record—not product quality—and makes missing procurement evidence explicit.

Engineering field coverage75%

9 of 12 selected fields published

  • Official product sourcepublished
  • Lifecycle statepublished
  • Mechanical dimensions / mass / mountingmissing
  • Environmental operating limitspublished
  • Supported protocolpublished
  • Channel configurationpublished
  • Bus / data ratepublished
  • Timestamp / latencyunknown
  • Electrical isolationpublished
  • Connector / host interfacepublished
  • Driver / software supportpublished
  • Power input / consumptionmissing
Procurement field coverage15%

2 of 13 selected fields published

  • Official product / sales routepublished
  • Lifecycle statepublished
  • Exact orderable SKU / part numbermissing
  • Price with region, currency and quantitymissing
  • Lead time with check datemissing
  • Commercial availability / stock statemissing
  • Minimum order quantitymissing
  • Authorized distributor / sales channelmissing
  • CAD / STEP / interface drawingmissing
  • Certification with identifiermissing
  • MTBF / failure / reliability datamissing
  • Warranty termsmissing
  • PCN / EOL / replacement noticemissing

Coverage measures whether a selected public field is present with non-U evidence. It is not a product score, compatibility result, certification, availability confirmation or procurement recommendation. Download the complete readiness coverage JSON →

MODEL-LINKED PHYSICAL EVIDENCE

1 bounded physical-evidence record.

Publisher independence, identity precision and measurement scope vary by row. Results remain bounded by the disclosed specimen, setup, workload and metric; an inconclusive mapping is evidence associated with the catalog model, not verification of a manufacturer claim.

Measured resultConditionsClaim mappingSource
Independent real-system experimentindependent_physical_evidenceMultiple physical stations showed a reproducible three-minute production-test slowdownWindows 10 and LabVIEW production test; oscilloscope confirmed bus transfer; root cause not isolated.inconclusiveThe record establishes bounded physical evidence for the named model, but the experiment does not reproduce the catalogued claim metric and conditions; the claim remains inconclusive.USB to CAN V2 compact speed issues ↗User test configuration and observations
Checked 2026-08-26
CLAIM LEDGER

Reported values, conditions attached.

Evidence state describes the claim—not the prestige of the company or document.

ClaimReported valueCondition / boundaryStateSource
CAN channelschannels1Single high-speed CAN channel.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 compact product page ↗Protocol, host, isolation and driver specifications
Checked 2026-08-10
Classical CAN bitratebus_bitrate10–1000 kbit/sHigh-speed CAN according to ISO 11898-2.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 compact Datasheet ↗D-Sub variant interface, isolation and environmental specifications
Checked 2026-08-10
CAN FD supportcan_fdNoSelected V2 compact record is classical CAN.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 compact product page ↗Protocol, host, isolation and driver specifications
Checked 2026-08-10
Host interfacehost_interfaceUSB 2.0 Hi-Speed, 480 Mbit/sHost scheduling and driver behavior still apply.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 compact Datasheet ↗D-Sub variant interface, isolation and environmental specifications
Checked 2026-08-10
Numeric timestamp resolutiontimestampNot published in cited specificationRCI checked the cited official specification on the verification date.The selected official specifications describe high-precision timestamping but do not publish a numeric resolution.U · UnknownHMS Ixxat USB-to-CAN V2 compact product page ↗Protocol, host, isolation and driver specifications
Checked 2026-08-10
Isolation withstandisolation1 kV DC for 1 s / 500 V AC for 1 minManufacturer datasheet value.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 compact Datasheet ↗D-Sub variant interface, isolation and environmental specifications
Checked 2026-08-10
Driver interfacessoftwareWindows VCI; Linux ECI / SocketCANExact current distribution and kernel support must be checked.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 compact product page ↗Protocol, host, isolation and driver specifications
Checked 2026-08-10
Operating temperatureenvironmental−20 to +70 °CManufacturer datasheet value.M · Manufacturer claimedHMS Ixxat USB-to-CAN V2 compact Datasheet ↗D-Sub variant interface, isolation and environmental specifications
Checked 2026-08-10

Known limits

What this record does not prove.

  • This V2 compact record does not support CAN FD.
  • Timestamp precision is not numerically specified.
  • The product page and cited D-Sub datasheet use different connector/order-number variants; the exact connector must be frozen in the BOM.