Motion & Actuation · Strain-wave gear unit

Harmonic Drive

CSF-14-50-2UH

An exact size-and-ratio gear-unit record. Published torque and stiffness values remain rating-table claims, not an RCI robot-joint duty-cycle, thermal, life or backlash test.

Architecture

Housed CSF-series strain-wave gear unit with integrated output bearing, size 14 and 50:1 nominal ratio

Identity

Harmonic Drive CSF-14-50-2UH · Also: CSF-2UH size 14 ratio 50, CSF-14-50-2UH gear unit

DECISION READINESS / 0.1

What this record can support today.

Coverage is computed from published, non-unknown fields. It measures the record—not product quality—and makes missing procurement evidence explicit.

Engineering field coverage55%

6 of 11 selected fields published

  • Official product sourcepublished
  • Lifecycle statepublished
  • Mechanical dimensions / mass / mountingpublished
  • Environmental operating limitsmissing
  • Continuous or rated outputpublished
  • Peak / momentary outputpublished
  • Speed boundarymissing
  • Transmission ratio / errorpublished
  • Electrical input / consumptionmissing
  • Control and communication interfacemissing
  • Position / torque feedbackmissing
Procurement field coverage15%

2 of 13 selected fields published

  • Official product / sales routepublished
  • Lifecycle statepublished
  • Exact orderable SKU / part numbermissing
  • Price with region, currency and quantitymissing
  • Lead time with check datemissing
  • Commercial availability / stock statemissing
  • Minimum order quantitymissing
  • Authorized distributor / sales channelmissing
  • CAD / STEP / interface drawingmissing
  • Certification with identifiermissing
  • MTBF / failure / reliability datamissing
  • Warranty termsmissing
  • PCN / EOL / replacement noticemissing

Coverage measures whether a selected public field is present with non-U evidence. It is not a product score, compatibility result, certification, availability confirmation or procurement recommendation. Download the complete readiness coverage JSON →

CLAIM LEDGER

Reported values, conditions attached.

Evidence state describes the claim—not the prestige of the company or document.

ClaimReported valueCondition / boundaryStateSource
Frame sizesize14Exact CSF-14-50-2UH table row.M · Manufacturer claimedHarmonic Drive CSF-2UH Gear Unit ↗CSF-2UH technical table; exact CSF-14-50-2UH row · Live official product table observed 2026-08-13
Checked 2026-08-13
Reduction ratioratio50:1Exact order-code suffix and table row.M · Manufacturer claimedHarmonic Drive CSF-2UH Gear Unit ↗CSF-2UH technical table; exact CSF-14-50-2UH row · Live official product table observed 2026-08-13
Checked 2026-08-13
Rated torquerated_torque5.4 N·mManufacturer L10-rated value for the exact table row; apply catalog rating conditions.M · Manufacturer claimedHarmonic Drive CSF-2UH Gear Unit ↗CSF-2UH technical table; exact CSF-14-50-2UH row · Live official product table observed 2026-08-13
Checked 2026-08-13
Repeated peak torquerepeated_peak_torque18 N·mManufacturer rating-table value; not a continuous operating point.M · Manufacturer claimedHarmonic Drive CSF-2UH Gear Unit ↗CSF-2UH technical table; exact CSF-14-50-2UH row · Live official product table observed 2026-08-13
Checked 2026-08-13
Momentary peak torquemomentary_peak_torque35 N·mManufacturer rating-table value; duration and duty conditions must be checked in engineering guidance.M · Manufacturer claimedHarmonic Drive CSF-2UH Gear Unit ↗CSF-2UH technical table; exact CSF-14-50-2UH row · Live official product table observed 2026-08-13
Checked 2026-08-13
Backdriving torquebackdriving_torque1.6 N·mManufacturer table value; integration, lubrication and temperature can affect system behavior.M · Manufacturer claimedHarmonic Drive CSF-2UH Gear Unit ↗CSF-2UH technical table; exact CSF-14-50-2UH row · Live official product table observed 2026-08-13
Checked 2026-08-13
Standard accuracystandard_accuracy1.5 arc minPublished standard-accuracy table value, not mounted-system accuracy.M · Manufacturer claimedHarmonic Drive CSF-2UH Gear Unit ↗CSF-2UH technical table; exact CSF-14-50-2UH row · Live official product table observed 2026-08-13
Checked 2026-08-13
Massmass0.52 kgExact table row.M · Manufacturer claimedHarmonic Drive CSF-2UH Gear Unit ↗CSF-2UH technical table; exact CSF-14-50-2UH row · Live official product table observed 2026-08-13
Checked 2026-08-13
Torsional stiffness K1 / K2 / K3torsional_stiffness0.19 / 0.24 / 0.34 ×10^4 N·m/radPiecewise manufacturer table values for the exact model.M · Manufacturer claimedHarmonic Drive CSF-2UH Gear Unit ↗CSF-2UH technical table; exact CSF-14-50-2UH row · Live official product table observed 2026-08-13
Checked 2026-08-13
Output-bearing moment stiffnessoutput_moment_stiffness4.38 ×10^4 N·m/radExact table row.M · Manufacturer claimedHarmonic Drive CSF-2UH Gear Unit ↗CSF-2UH technical table; exact CSF-14-50-2UH row · Live official product table observed 2026-08-13
Checked 2026-08-13
Robot-joint thermal duty enveloperobot_joint_thermal_envelopeNot published in cited public evidenceRCI checked the cited official public evidence on the verification date.The cited catalog does not define one universal robot-joint motor, housing, lubrication, cooling, ambient and motion-cycle envelope for this record.U · UnknownHarmonic Drive Reducer Catalog ↗CSF series engineering, rating and application boundaries · Official reducer catalog observed 2026-08-13
Checked 2026-08-13
Independent mounted life and backlash validationindependent_life_validationNot published in cited public evidenceRCI checked the cited official public evidence on the verification date.RCI has not received, instrumented, endurance-tested or teardown-inspected this gear unit.U · UnknownHarmonic Drive Reducer Catalog ↗CSF series engineering, rating and application boundaries · Official reducer catalog observed 2026-08-13
Checked 2026-08-13

Known limits

What this record does not prove.

  • Gear-unit ratings do not establish a complete motor, encoder, brake, housing, lubrication or thermal design.
  • Peak values must not be represented as continuous output capability.
  • No RCI physical specimen, joint integration, life test or teardown evidence exists.